Inquiry
Leave Your Message

SC-NS531608T4M-DL

28 Port 10G L3 Managed Industrial Ethernet Switch

◆ Features dual-side output interfaces alongside a dedicated signal trigger for single power loss warning notifications
◆ Physical Ports: Composed Of 8 100/1 Gbps Optical Ports + 16 1 Gbps Electrical Ports + 4 10 Gbps/1 Gbps Optical Ports 
◆ Overall switch throughput capacity reaches 128 Gbps, while the maximum packet forwarding performance hits 95.23 Mpps
◆ Layer 3 routing mechanism supports diverse protocol suites such as RIP, OSPF, OSPFv3, BGP, VRRP, BFD, IGMP and PIM
◆ Core software capabilities comprise QoS traffic control, VLAN partitioning, DHCP address allocation, LACP link bundling, RMON statistics, IGMP multicast and IPv6 networking
◆ System configuration and maintenance can be realized via SNMP management protocol, Console local port, Telnet remote control and online web management page
◆ High-speed ring network self-healing system achieves ERPS recovery time under 20ms, and supports STP/RSTP/MSTP spanning tree mechanisms
◆ Robust industrial design provides IP40 enclosure protection, 6-kilovolt lightning resistance, surge protection circuitry, solid steel alloy casing and fanless rack-mounted structure
◆ Dual redundant power supply module supports wide-range AC/DC input voltage between 110V and 265V
◆ The device works stably at operating temperatures of -30°C to 75°C and preserves safely at storage temperatures from -30°C to 85°C

    SC-NS531608T4M-DL belongs to the category of controllable industrial high-speed 10G Ethernet switching equipment, which is fitted with four pieces of 100/1000/10G adaptive SFP/SFP+ fiber sockets, eight groups of 100/1000 Base-X standard SFP optical interfaces and sixteen sets of 10/100/1000 Base-T auto-sensing RJ45 electrical access ports. All the equipped four fiber interfaces, eight gigabit optical ports and sixteen general Ethernet access ports are produced in strict accordance with rigid industrial design norms as well as high-standard raw material selection rules. This network hardware adopts 19-inch alloy metal outer shell structure, matched with front-side status indicator panel and rear end wiring layout design. It can adapt to extremely wide ambient temperature environments and adopt dual redundant power supply design that fits AC and DC voltage input ranging from 110V to 265V, which steadily endows the whole equipment with outstanding industrial operating capability, superb cold and heat resistant property as well as reliable lightning surge defense performance. This network switch carries abundant practical control modules, covering whole machine operation supervision, full-spec Layer 2 network control, network safety defense setup, three-layer cross-network forwarding, data flow priority scheduling and all-round network running state inspection & daily maintenance services. Built-in three-level industrial anti-static shielding structure enables this product to get stable running conditions inside intelligent traffic systems, outdoor video monitoring projects, factory local area networks, urban smart construction scenes and other severe working surroundings. With no built-in cooling fan structure, low energy consumption layout and professional industrial manufacturing craft, it can run stably within the temperature scope from minus 30 degrees Celsius up to 75 degrees Celsius, offering high cost-performance network deployment solutions for diverse industrial application occasions. This kind of network gear gains wide promotion and application in intelligent office buildings, urban smart construction projects, digital residential quarters, modern traffic control platforms, communication signal transmission, safety monitoring systems, financial transaction platforms, customs inspection departments, sea route transportation facilities, power grid projects, water conservancy engineering items and oil field sites that demand large-flow data signal transmission work.
    It can realize stable data docking with network safety monitoring terminals by adopting standard SNMP communication rules, and deliver various core device data such as online-offline running states, fixed MAC binding records, staff login operation logs, personal parameter adjustment traces, internal parameter modification content and real-time port link on-off conditions toward safety supervision platforms. Relevant data transmission modes include passive data query acquisition and active automatic information push, which fully satisfy the access access criteria formulated for electric power industry safety networks.

    Model​
    SC-NS531608T4M-DL​
    Business Interface 4*100/1000/10G Base-X SFP/SFP+,8 100/1 Gbps optical ports , 16 1 Gbps electrical ports
    Management interface   1 Console RJ45 control port
    Power interface The 5P Phoenix terminal supports optional single or dual power supply configurations.
    Power Alert 3P Phoenix Terminal
    LED Light Power indicator light: PWR (green); Optical port indicator light: FX (green); Network port indicator light: yellow; Front and rear light boards
    Cable type and distance
    Single mode fiber 20/40/60/80/100KM
    Multimode (optical) fibre 550m/2KM
    Fiber Optic Interface LC/SC
    Network topology & scale
    Star topology Support
    Bus topology Support
    Tree topology Support
    Electrical character
    input voltage DC37-75V/AC110-265V 50-60HZ Dual power
    power dissipation full load (total power) < 34W
    Layer 2 Switching
    Exchange capacity 128G
    Packet forwarding rate 95.23Mpps
    MAC address list 16K
    VLAN Support & Qty Support 4K
    Report Buffer 12M
    Forward delay <10us
    Port Characteristics Cross Direct Connection Adaptive
    Flow control Support
    Giant Frame Support 12Kbytes
    Storm Suppression Support
    Spanning Tree Protocol Support STP/RSTP/MSTP
    Server Configuration Radius/DHCP/ TACACS+
    Ring Protocol Support ERPS
    Link Aggregation Supports 8 groups
    Multicast Support IGMP /MVR
    Port Mirror Support
    Storm Suppression Supports unicast/multicast/broadcast
    Port Traffic Statistics Support
    Port Traffic Statistics Support
    Vlan Support access、trunk、General Model,Support GVRP/GMRP/MAC address-based VLAN/IP address segment-based VLAN/Voice VLAN configuration
    QINQ Support 
    LLDP Support
    DHCPSERVER Support
    DHCPL2 Relay Agent Support
    IP RELAY agent Support
    DHCPv6SERVER Support
    DHCPv6relay Support
    DNS Support
    Port speed limit Support
    User Configuration Supports viewing and writing at two levels
    MAC Address Study Support
    MAC Address Binding Support IP/VLAN/Port Binding
    IPV4/IPV6 configure Support
    Manage VLAN configuration Support
    UDLD Support
    Ring Network Protection Support
    L3 manage Supports both IPv4 and IPv6 stacks, as well as IPv4 and IPv6 static and default routes.
    IP grade IP40
    Power surge protection IEC 61000-4-5 Level 3(4KV/2KV)(8/20us)
    Radiation immunity IEC 61000-4-3 Level 3 (10V/m)
    Instantaneous pulse anti-interference IEC 61000-4-4 Level 3 (1V/2V)
    Conduction Anti-interference IEC 61000-4-6 Level 3 (10V/m)
    Power frequency magnetic field interference suppression IEC 61000-4-8 Level4(30A/m)
    Voltage drop IEC 61000-4-11 Level3 (10V)
    EMI CLASS A
    Anti-static interference IEC 61000-4-2 Level 4 (15KV/30KV)
    Free Fall 0.5m
    Network Security Control
    Access Control List (ACL) Supports 500 ACL entries;
    Supports IP standard ACL;
    Supports MAC extended ACL;
    Support IP-based ACL expansion;
    Authentication Management Support 802.1x/Enable/HTTP/HTTPs/Dot1x
    DOS manage Support DOS attack configuration
    Port Security Support
    Port Isolation Support
    privately-owned vlan Support
    Dhcp-snooping Support
    IPSG Support
    Dynamic ARP Check Support
    Quality of service (QOS) Supports 802.1P priority
    Support IP DSCP priority
    Support port queue priority
    Support QoS queue discard priority
    Management function
    Command line Support
    Manage serial port Support
    Telnet Support
    SSH Support
    WEB Manage Support
    SNMP Support SNMPv1/v2c/V3
    Sflow Support
    user management Support
    System log Support
    File Upgrade Support
    file transfer Support tftp、ftp、scp、sftp
    Firmware upgrade Supports dual firmware management
    Device restart Support
    Device Diagnosis Support PINGV4/PINGV6/Traceroute IPv4/Traceroute IPv6
    SFP module DDM Support
    Environment condition
    Working temperature -30℃~+75℃
    Storage/Transport Temperature -30℃~+85℃
    Relative humidity 5%~95% Condensation is not supported(non-condensing)
    Heat dissipation method Fanless design for natural heat dissipation
    MTBF 100,000 Hours
    Physical construction
    Size 440X250X44.5mm
    Way to install Standard 19-inch rack installation
    Weight 2.5KG
    Shell material Industrial steel alloy casing
    Support and Accessories
    Corollary equipment Equipment, terminals, certificate of conformity, instruction manual
    SCS
    Available Models Gigabit Copper Port Gigabit SFP 10Gigabit SFP+ Power Supply
    SC-NS531608T4M-DL 16 8 4 90-265VAC(110-330VDC) Power Supply
    SC-NS531608T4M-DL-A2 16 8 4 90-265VAC(110-330VDC) dual power supply

    Make An AppointmentLeave Your Message