- Industrial-Grade Switches
- Carrier-grade Switches
- Multifunctional Wireless Series
- Industrial Gateway Series
- Other Communication Products
SC-NS531608T4M-DL belongs to the category of controllable industrial high-speed 10G Ethernet switching equipment, which is fitted with four pieces of 100/1000/10G adaptive SFP/SFP+ fiber sockets, eight groups of 100/1000 Base-X standard SFP optical interfaces and sixteen sets of 10/100/1000 Base-T auto-sensing RJ45 electrical access ports. All the equipped four fiber interfaces, eight gigabit optical ports and sixteen general Ethernet access ports are produced in strict accordance with rigid industrial design norms as well as high-standard raw material selection rules. This network hardware adopts 19-inch alloy metal outer shell structure, matched with front-side status indicator panel and rear end wiring layout design. It can adapt to extremely wide ambient temperature environments and adopt dual redundant power supply design that fits AC and DC voltage input ranging from 110V to 265V, which steadily endows the whole equipment with outstanding industrial operating capability, superb cold and heat resistant property as well as reliable lightning surge defense performance. This network switch carries abundant practical control modules, covering whole machine operation supervision, full-spec Layer 2 network control, network safety defense setup, three-layer cross-network forwarding, data flow priority scheduling and all-round network running state inspection & daily maintenance services. Built-in three-level industrial anti-static shielding structure enables this product to get stable running conditions inside intelligent traffic systems, outdoor video monitoring projects, factory local area networks, urban smart construction scenes and other severe working surroundings. With no built-in cooling fan structure, low energy consumption layout and professional industrial manufacturing craft, it can run stably within the temperature scope from minus 30 degrees Celsius up to 75 degrees Celsius, offering high cost-performance network deployment solutions for diverse industrial application occasions. This kind of network gear gains wide promotion and application in intelligent office buildings, urban smart construction projects, digital residential quarters, modern traffic control platforms, communication signal transmission, safety monitoring systems, financial transaction platforms, customs inspection departments, sea route transportation facilities, power grid projects, water conservancy engineering items and oil field sites that demand large-flow data signal transmission work.
It can realize stable data docking with network safety monitoring terminals by adopting standard SNMP communication rules, and deliver various core device data such as online-offline running states, fixed MAC binding records, staff login operation logs, personal parameter adjustment traces, internal parameter modification content and real-time port link on-off conditions toward safety supervision platforms. Relevant data transmission modes include passive data query acquisition and active automatic information push, which fully satisfy the access access criteria formulated for electric power industry safety networks.
Model
|
SC-NS531608T4M-DL
|
| Business Interface | 4*100/1000/10G Base-X SFP/SFP+,8 100/1 Gbps optical ports , 16 1 Gbps electrical ports |
| Management interface | 1 Console RJ45 control port |
| Power interface | The 5P Phoenix terminal supports optional single or dual power supply configurations. |
| Power Alert | 3P Phoenix Terminal |
| LED Light | Power indicator light: PWR (green); Optical port indicator light: FX (green); Network port indicator light: yellow; Front and rear light boards |
| Cable type and distance | |
| Single mode fiber | 20/40/60/80/100KM |
| Multimode (optical) fibre | 550m/2KM |
| Fiber Optic Interface | LC/SC |
| Network topology & scale | |
| Star topology | Support |
| Bus topology | Support |
| Tree topology | Support |
| Electrical character | |
| input voltage | DC37-75V/AC110-265V 50-60HZ Dual power |
| power dissipation | full load (total power) < 34W |
| Layer 2 Switching | |
| Exchange capacity | 128G |
| Packet forwarding rate | 95.23Mpps |
| MAC address list | 16K |
| VLAN Support & Qty | Support 4K |
| Report Buffer | 12M |
| Forward delay | <10us |
| Port Characteristics | Cross Direct Connection Adaptive |
| Flow control | Support |
| Giant Frame | Support 12Kbytes |
| Storm Suppression | Support |
| Spanning Tree Protocol | Support STP/RSTP/MSTP |
| Server Configuration | Radius/DHCP/ TACACS+ |
| Ring Protocol | Support ERPS |
| Link Aggregation | Supports 8 groups |
| Multicast | Support IGMP /MVR |
| Port Mirror | Support |
| Storm Suppression | Supports unicast/multicast/broadcast |
| Port Traffic Statistics | Support |
| Port Traffic Statistics | Support |
| Vlan | Support access、trunk、General Model,Support GVRP/GMRP/MAC address-based VLAN/IP address segment-based VLAN/Voice VLAN configuration |
| QINQ | Support |
| LLDP | Support |
| DHCPSERVER | Support |
| DHCPL2 Relay Agent | Support |
| IP RELAY agent | Support |
| DHCPv6SERVER | Support |
| DHCPv6relay | Support |
| DNS | Support |
| Port speed limit | Support |
| User Configuration | Supports viewing and writing at two levels |
| MAC Address Study | Support |
| MAC Address Binding | Support IP/VLAN/Port Binding |
| IPV4/IPV6 configure | Support |
| Manage VLAN configuration | Support |
| UDLD | Support |
| Ring Network Protection | Support |
| L3 manage | Supports both IPv4 and IPv6 stacks, as well as IPv4 and IPv6 static and default routes. |
| IP grade | IP40 |
| Power surge protection | IEC 61000-4-5 Level 3(4KV/2KV)(8/20us) |
| Radiation immunity | IEC 61000-4-3 Level 3 (10V/m) |
| Instantaneous pulse anti-interference | IEC 61000-4-4 Level 3 (1V/2V) |
| Conduction Anti-interference | IEC 61000-4-6 Level 3 (10V/m) |
| Power frequency magnetic field interference suppression | IEC 61000-4-8 Level4(30A/m) |
| Voltage drop | IEC 61000-4-11 Level3 (10V) |
| EMI | CLASS A |
| Anti-static interference | IEC 61000-4-2 Level 4 (15KV/30KV) |
| Free Fall | 0.5m |
| Network Security Control | |
| Access Control List (ACL) | Supports 500 ACL entries; Supports IP standard ACL; Supports MAC extended ACL; Support IP-based ACL expansion; |
| Authentication Management | Support 802.1x/Enable/HTTP/HTTPs/Dot1x |
| DOS manage | Support DOS attack configuration |
| Port Security | Support |
| Port Isolation | Support |
| privately-owned vlan | Support |
| Dhcp-snooping | Support |
| IPSG | Support |
| Dynamic ARP Check | Support |
| Quality of service (QOS) | Supports 802.1P priority Support IP DSCP priority Support port queue priority Support QoS queue discard priority |
| Management function | |
| Command line | Support |
| Manage serial port | Support |
| Telnet | Support |
| SSH | Support |
| WEB Manage | Support |
| SNMP | Support SNMPv1/v2c/V3 |
| Sflow | Support |
| user management | Support |
| System log | Support |
| File Upgrade | Support |
| file transfer | Support tftp、ftp、scp、sftp |
| Firmware upgrade | Supports dual firmware management |
| Device restart | Support |
| Device Diagnosis | Support PINGV4/PINGV6/Traceroute IPv4/Traceroute IPv6 |
| SFP module DDM | Support |
| Environment condition | |
| Working temperature | -30℃~+75℃ |
| Storage/Transport Temperature | -30℃~+85℃ |
| Relative humidity | 5%~95% Condensation is not supported(non-condensing) |
| Heat dissipation method | Fanless design for natural heat dissipation |
| MTBF | 100,000 Hours |
| Physical construction | |
| Size | 440X250X44.5mm |
| Way to install | Standard 19-inch rack installation |
| Weight | 2.5KG |
| Shell material | Industrial steel alloy casing |
| Support and Accessories | |
| Corollary equipment | Equipment, terminals, certificate of conformity, instruction manual |
| Available Models | Gigabit Copper Port | Gigabit SFP | 10Gigabit SFP+ | Power Supply |
| SC-NS531608T4M-DL | 16 | 8 | 4 | 90-265VAC(110-330VDC) Power Supply |
| SC-NS531608T4M-DL-A2 | 16 | 8 | 4 | 90-265VAC(110-330VDC) dual power supply |

Industrial-Grade Switches
Carrier-grade Switches
Multifunctional Wireless Series
Industrial Gateway Series
Other Communication Products